lab biological waste incineration

1- There are more than 4000 Cubic Meter sludge are packed in Plastic Bags & stored more than 10 years
2- Cleaning and treated 2500 Cubic Meters inside the Oil Tank.
– the waste is biological and coming from lab, can be heavily hazardous in case of terror attack or epidemics or similar events.
– the input is low and occasional, the lab is used when terror or epidemy alarm occures. But occasionly incineration of human or animal carcasses can be demanded.mobile incinerator to work along with a mobile biolab for first responders.is the smallest incinerator available in the market. incinerator of capacities of 10kg/h and 20 kg/h for hospital waste.

medical was incinerators Department of Health

hospital waste management team at a tertiary care hospital ,1250 beeded hsopital .

our daily waste generated from all sources is 0.55kg/bed/day =685kg/day

we need an incinerator of 150kg/hour loading capacity.

plz reply with , buying,installation, running and maintenance cost.incinerators, specifically, medical was incinerators
Department of Health has floated a tender for Incinerator X 1 Unit and the closing date is on 16th June 2011. The specification of the Incinerator is as below:

Specification of Incinerator

1.    Should have preparation, Incineration, Scrubber steps to burn waste completely and waste gas should be non-polluted

2.    Heavy duty steel, heat resistant coating, stainless steel lid, painted tubular steel frame, 2-blowers, axial vane, suitable drum (S/S, thick) for the incinerator must be provided.

3.    Approx. 20 to 25 Kg per batch and the time required for 1 batch not more than 1 hour on average.

4.    Ash should be only 5% of the waste material

5.    Weight of Incinerator – 50-60 Kg

6.    220V AC

7.    Surgical , medical & laboratory waste

8.    B X L X H = 4 feet X 8 feet X 6 feet

9.    1 year warranty

10. ISO Certified

11. Mobile Incinerator

12.  Electric

MUNICIPAL SOLID WASTE INCINERATORS

a specific type to use at a crematorium. Something that allows specifically for ash collection etc.cremation option to the deceased’s family. Is this product suitable, are ashes easily collected etc. a cremator, for pet clinic, could you introduce and all detail of sales, tax, environtment.-Plastic. 500Kg/hr and to be used maximum 6 times, is this means it will provide only 3 tons per day? Noting that project documents requires 10 tons/day
Plastic bottle-
-Rags & oiled
Glass bottles and aluminum-
-Oils
Fat-
Filter, tires, belts
-Chemicals, paint
Household waste-
Municipal incinerators with a 10-metric ton/24-hour capacity, complete with Stacks, control panels and all accessories, complying with 01015 par. 5.16.1
LOT
2.0

Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks, control panels and all accessories , complying with 01015 par. 5.16.2
MUNICIPAL SOLID WASTE INCINERATORS

Municipal waste incinerator quantities and capacities shall be designed for 24-hour 7-day-a-week continuous operation.

Incinerators shall be capable of processing both wet and dry material and operating on either diesel fuel, JP-8 fuel,

or waste oil; see Plumbing for fuel storage system requirements. The following shall be provided as a minimum:

Reinforced concrete mounting foundations, feed or charging hoppers (or loaders), primary combustion chambers

with ash cleanout doors, secondary combustion chambers with ash cleanout doors, cyclone air filters (or separators),

and forced air exhaust stacks (or chimneys).

The charging system shall consist of, as a minimum, a hopper for top feeding and mechanically operated hydraulic

charging ram or augur. To prevent warpage or excessive thermal expansion, a charger cooling system using either

air or water shall be provided.

Primary combustion chamber shall be either the rotary- or stationary fixed-hearth (or kiln) type incinerator. Burner

and combustion air controls shall be fully automatic comprising of, as a minimum, electronic ignition and all

necessary interlocks and safety devices to provide safe operation. The chamber and burner shall be designed to

maintain a minimum combustion temperature of at least 700 to 870 C (1300 to 1600 F), but shall not to exceed 980

C (1800 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

pit where cooled by water and removed by conveyor.

Secondary combustion chamber shall be either the rotary- or stationary-hearth (or kiln) type incinerator designed to

oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be fully automatic

comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe

operation. The chamber and burner shall be designed to maintain a minimum combustion temperature of at least

930 to 980 C (1700 to 1800 F), but shall not to exceed 1150 C (2100 F). The ash-removal system shall consist of, as

a minimum, the direct manual removal into a dry

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

particles.

5.16.2 MEDICAL WASTE INCINERATORS

Medical waste incinerators shall be specifically designed by the manufacturer to dispose of all medical wastes. All units shall be designed for 8 hours

per day of continuous operation and be rated in quantity per hour (i.e. kg/hr or lbs/hr).

Incinerator loading or charging of medical waste shall be batched-fed manually.

Primary combustion chamber shall be the stationary fixed-hearth (or kiln), multiple-chamber, retort type or larger

capacity rotary-hearth (or kiln) type. Burner and combustion air controls shall be fully automatic comprising of, as a

minimum, electronic ignition and all necessary interlocks and safety devices to provide safe operation. The

chamber and burner shall be designed to maintain a minimum combustion temperature of at least 760 to 870 C

(1400 to 1600 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

pit where cooled by water and removed by conveyor.

Secondary combustion chamber shall be a solid-walled and -floored, horizontal, refractory-lined cylinder type

incinerator designed to oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be

fully automatic comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to

provide safe operation. The chamber and burner shall be designed to maintain a minimum combustion temperature

of at least 930 to 1200 C (1700 to 2200 F) with a minimum gas residence (or dwell) time of 2.0 seconds. The ashremoval

system shall consist of, as a minimum, the direct manual removal into a dry collection hopper.

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

particles.

5.16.3 INCINERATOR STACKS (OR CHIMNEYS)

Stack size shall be in accordance with the manufacturer’s recommendations. Stacks shall be the forced-air type and

completely self-supporting and unattached to nearby structures. As a minimum, stack heights shall minimize

downwash of stack emissions due to aerodynamic influences from nearby structures and be calculated in accordance

with DoD 4715.05-G, Overseas Environmental Baseline Guidance Document. Stacks shall be provided with

corrosion-resistant steel weather caps.”

Incinerators

burn between 5000-10000 kg per hour.Mostly waste from crude oil tanks. construction, installation and 6 months maintenance cost including specifications.CMSD for Double Chamber Rotary Klin Type Incinerator (1st Chamber temperatur not less than 850 degree centrigrade & 2nd Chamber Temperature  not less than 1200 c with exhaust pipe 100 meter long with emission gas filtering mechanism ),  Hydroclave (Medical) with anciliary equipments operating parameters : Temperature 250-275 degree feren , Pressure 15-35PSI , Sterilization time 30 minus , Batch capacity -463 kg . two Incinerators for a hospital in VN. The anticipated capacity is approximately 1,000 kg per day.

Hot Sale Small Scale Waste Incinerators 30 and 50 kgs per hour capacity

Incenerator System

 

Incenerator
Supply, installation and testing of medical waste incinerator with a capacity of 75 kilograms / hour, operated by LPG and including all accessories with chimney in accordance with the technical specifications and public health regulations Item 2
Incinerators room for 3 incinerators as item 3-1-1, and waste store for keeping wastes for 7 days, including all constructions by reinforced concrete with Incenerator and store equipment, all wiring, lighting, water supply and drainage Item 1
Provide Incinerators room & waste store with fire fighting system, including sprinklers, approval of water source at site, fire alarm system contains sensors for heat & smoke, to be linked with the hospital fire alarm systems Item 1
Supply, installation & testing of ventilation system of Incenerator room & store by ROOF TOP EXHAUST FANS with HEPA FILTER, rate of change of air 5 times per hour, with ducts and air grills Item 1
Supply, installation & testing DUCTED SPLIT UNITS at waste store with sufficient capacity to maintain the internal temperature at 14 degrees Celsius in summers and winters Item 1

Gas Incinerator medical waste

Recently one of clients informed us their intention to procure 1 unit Gas Incinerator.medical waste incinerator to burn the wastes of hospitals in Egypt , the capacity required is 5 tons per day.the medium incinerator that uses both electricity and oil.A SMALL PET CREMATORY WITH GAS

INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

hospital for burning hazardous waste and chimicals

use in the hospital for burning hazardous waste and chimicals, minimum Capacity 300 per hour. I will be reselling to my client?. Below is the information I was given and nothing else. The hospital incinerator for use in the clinical waste as required by international environmental management. Minimum 300 Kg capacity/hr, Fuel fired, refractory lined, chimney and sampling prot. Minimum temperature of 1100 degree Celsiu.the incinerator machine for burn 500kg per hour. project about burn medical waste of the hospitals.Just want to price of you various types of Medical Rubbish Incinerators.need all information on 300 kg per hour unit.  availability.  operational costs using diesel (other).the waste is Human Tissues. And we have 10 kg per day; we need incinerator for medical waste.Burn Capacity: 50kgs per hour (Average capacity according to Medical Waste).please forward information about pricing on all of you pet crematory models.Regarding Gas Incinerator, Please note that Fuel for the Incinerator
will be Gas. As gas is chip in our country.

burning hazardous waste and chimicals incinerators

3 types of incinerators, which are 10Kgs, 20Kgs and 30Kgs for our Tawfiq Hospital use in Malindi, Kenya. we are an

environmental consulting firm as I’ve mentioned previously, we have already contracted with a French company specialized in

the sale of solid waste incinerators (ATI) and we bought a crematorium for the disposal of solid waste, including $ 180

thousand dollars, and now we want to get into the business of selling waste incinerators animal, and since it does not have an

agent in Saudi Arabia.  The three models you have indicated are based on 24 hour operation. Could you please make suitable

recommendations for 8-10 hour shift each day (including cooling time)? I assume we will need bigger capacity incinerators for

each of the three requirements.I am interested to know more detailed specifications and prices for your SYC-20 incinerator. I

am in the market for a small and easy-to-operate incinerator, however have little to no experience with such items.

installation and construction of SOLID WASTE
MANAGEMENT COMPLEX , for that purpose we need Sixteen (16) ton/day (7,538 kg/day) Capacity Incinerator System.1.5 ton garbage

per day,

required number of units -10 to 25 numbers

Installing different type of waste Management systems preferably Incineration and others for the state Jammu & Kashmir India

manufacturer and exporter of various Incinerator and other products.

Please be noted that we are a leading Bangladeshi business house dealing in various Medical, Surgical, Dental, Hospital

products, Plant and Machinery and so on

Most important is transformer, 220v motor, Temperature thermocouple, Blower of Primary Burner.

base on this portable incinerator,
1. the type of waste it can be use for (treatment).Hospital waste incinerators with reduced or carbon dioxide  CIF khartom –

Sudan

medical waste incinerators models for hospitals of 100-300 bed and 100-1000bed,kindly send price quote of all the YD models

and mode of transaction /delivery to nigeria

incinerator is for use in the hospital for burning hazardous waste and chimicals, minimum Capacity 300 per hour.

The hospital incinerator for use in the clinical waste as required by international environmental management. Minimum 300 Kg

capacity/hr, Fuel fired, refractory lined, chimney and sampling prot. Minimum temperature of 1100 degree Celsius kindly quote

me best price for resale.The best price for resale for the between $7000 to $12000 Usd I already have quotations just need the

best price please. price should be CIF Johannesburg or Durban