waste_incinerator_27

INCINERATOR for Kenya

Product Description

  1. Capacity of destruction in weight: 60Kg/h
  2. It should be able to operate not less than 10 hours/day.
  3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc..
  4. Design Specification: Types A, B, C, D and E of medical waste
  5. “PYROLYTIC” combustion by controlling the gasification of waste.
  6. The incinerator must avoid the release of black smoke and fine dust, (smokeless) during the loadings.
  7. It should be able to reduce the volume of wastes by 98%
  8. It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.
  9. The incineration should be completely free from visible smoke as well as offensive odours.
  10. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
  • the temperatures of combustion: Minimum will be 850oC and max 1400oC
  • post combustion:>1100oC
  1. The internal diameter of the chimney:Ø400 and its height: 8m
  2. The volume of the combustion chamber: 1,200L
  3. The dimension of the door for loading in cm: 70 x 70
  4. Burner operation should be automatic on/off
  5. Fuel: diesel
  6. The supplier must provide necessary information for the best of the installation. This incinerator with “PYROLYTIC” combustion must have:
  7. A combustion chamber of waste:
  • Perfectly tight door for the manual loading of waste. The loading should be manual, batch load.
  • A burner of lighting which the use is limited to the ignition of waste.
  • Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
  • The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal.
  • Composition of the refractory;
  • Refractory concrete:
  • Thickness :>100mm
  • Nature: 42% of Al203
  • Insulate in fibrous panels:
  • Thickness: >75mm
  • Nature: Calcium silicate.
  • Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
  • Plate of combustion in Carborundum, avoiding the fixing of glass and slags.
  1. A chamber of post combustion of gases
  • A burner of combustion of gases,
  • A device of injection of air allowing a total re-combustion of gases,
  • A device of air inlet of cooling of waste gases,
  • A sheath of evacuation of the gases burnt,
  • Carcass in strong sheet steel with support of connection
  • Composition of the refractory;
  • Refractory concrete:
  • Thickness :>150mm
  • Nature: 65%% of Al203
  • Insulate in fibrous panels:
  • Thickness: >85mm
  • Nature: Calcium
  • Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
  • A secondary injection of air to ensure perfect oxygen content.
  1. A control box ensuring the complete cycle of combustion.
  2. Fan:
  • Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
  1. Controls and regulations:

Control box watertight to dust, including:

  • A switch circuit breaker for each engine (ventilators and burners).
  • A timer with adjustable temporization for the regulation of each burner.
  • A regulator with digital watching for the temperature of combustion.
  • A regulator with digital watching for the temperature of post-combustion.
  • Electric box.
  1. The de-ashing must be done in the bottom of the combustion chamber or the de-ashing should be automatic or manual batch de-ashing.
  2. Process filtering system: scrubber to be mentioned as optional
  3. Emission standards compliance: BS 3316 or equivalent standard
  4. Capacity to treat plastic: not less than 40% by weight
  5. CE manufacturing compliance: BS EN 746-2-1997
Model YD-50
Burning Rate 50 kgs/hour
Feed Capacity 150 kgs
Paimary Combustion Chamber 900 Liters
Secondary Combustion Chamber 300 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 0.7Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 12.1–23.9 kg/hour
Gas Consumption (Natural Gas) 9.9–26.1 m3/hour
Internal Dimensions 120 x 90 x 85cm (paimary chamber)
External Dimensions 200 x 160 x 310cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 62 x 80cm
Chimney Length 5.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 4000 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal